2mm Frazier Suction Tube - ENT Surgical Instrument for Ear Wax Removal and Aural Microsuction
The 2mm Frazier suction tube is a precision ENT surgical instrument designed for controlled, gentle ear wax removal and aural microsuction in clinical settings.
The slim 2mm angled shaft provides excellent access and visibility in the ear canal, while the finger vent gives instant suction control for accurate, patient-friendly procedures.
Manufactured from theatre grade stainless steel, this reusable instrument is built for the demands of high-volume ENT, audiology and primary care services.
Supplied by Charles Medical, a UK medical supplies specialist.
Why clinicians choose this Frazier suction tube
-
2mm tip — fine, targeted suction for precise work in narrow ear canals
-
Angled shaft — improved access and clear line of sight during microsuction
-
Finger vent control — instant, one-handed suction adjustment for gentle, accurate cerumen removal
-
Supplied with stylet — keeps the lumen clear between cases for consistent flow
-
Smooth internal bore — supports reliable, uninterrupted suction throughout the procedure
-
Polished stainless steel finish — minimises snagging, easy to decontaminate, corrosion-resistant
-
Reusable and autoclavable — supports cost control and sustainable clinical practice
Clinical applications
- Ear wax removal and cerumen management
- Aural microsuction procedures
- ENT outpatient and theatre procedures
- Neurosurgical and microsurgical suction
- Nasal and throat suction in ENT settings
- Foreign body retrieval from the ear canal
Suitable for
- ENT outpatient departments and theatres
- Audiology clinics and microsuction services
- GP surgeries and primary care
- Community ear care providers
- Neurosurgery and microsurgery teams
Specifications
- Instrument type: Frazier suction tube
- Tip diameter: 2mm (6 Fr)
- Shaft: Angled for canal access
- Control: Finger vent for suction regulation
- Material: Theatre grade stainless steel
- Finish: Smooth polished
- Includes: Matching stylet for lumen clearing
- Use: Reusable — compatible with standard autoclave decontamination
- Origin: Pakistan
- Supplied by: Charles Medical
Pack options
-
3 tubes (GTIN: 5065021841587) — ideal for single-practitioner use or to trial the instrument
-
5 tubes (GTIN: 5065021841648) — keep multiple instruments in rotation between patients
-
10 tubes (GTIN: 5065021841693) — best value for high-volume ENT services and busy microsuction clinics
Use and care
Follow your local decontamination protocol before first use and between patients.
Inspect the tip, vent and lumen before each session. Use the stylet to clear the bore if required. Store dry to maintain finish and prolong instrument life.
Stock multiple tubes to eliminate downtime between patients during decontamination cycles.
Pair with otoscope specula, sterile gloves, suction tubing and a microsuction unit for a complete ear care setup.
Frequently asked questions
What size Frazier suction tube is best for ear wax removal?
A 2mm (6 Fr) Frazier suction tube is the most widely used size for aural microsuction and ear wax removal in ENT and audiology clinics. The 2mm tip provides precise, targeted suction in narrow ear canals while minimising patient discomfort. Larger sizes such as 3mm or 4mm are typically reserved for theatre or nasal procedures where higher flow is needed.
What is a Frazier suction tube used for?
A Frazier suction tube is an ENT surgical instrument used to remove fluid, wax, blood or debris from the ear canal, nasal cavity or surgical field. It is commonly used in aural microsuction, ear wax removal clinics, ENT outpatient procedures, neurosurgery and microsurgery. The finger vent allows the clinician to control suction pressure precisely, making it suitable for delicate procedures close to the tympanic membrane.
Is a Frazier suction tube reusable?
Yes. This stainless steel Frazier suction tube is fully reusable and compatible with standard autoclave decontamination. Follow your local decontamination protocol between patients. The included stylet helps clear the lumen before sterilisation. Reusable instruments reduce per-procedure cost and support sustainable clinical practice compared to single-use alternatives.
What is the difference between a Frazier suction tube and a Zoellner suction tube?
Both are ENT suction instruments, but they differ in design. A Frazier suction tube has an angled shaft and a finger vent for suction control, making it well suited to ear canal work and microsuction. A Zoellner suction tube has a straighter profile and is more commonly used in middle ear and mastoid surgery. For routine ear wax removal and aural microsuction, the Frazier design is the standard clinical choice.
How do I clean and sterilise a Frazier suction tube?
After each use, flush the lumen with water and use the stylet to clear any debris from the bore. Clean externally with an approved detergent solution. Sterilise using your facility’s standard autoclave cycle in line with local decontamination guidelines (HTM 01-01 or equivalent). Inspect the tip and vent for damage before returning to service. Store dry to maintain the polished finish.
Can a Frazier suction tube be used with any microsuction unit?
Yes. This 2mm Frazier suction tube connects to standard suction tubing and is compatible with most clinical microsuction units used in ENT and audiology settings. Ensure the connector size matches your suction unit tubing before use. The finger vent allows you to regulate suction pressure independently of the unit setting, giving you precise control during the procedure.
What is the French gauge (Fr) of a 2mm Frazier suction tube?
A 2mm Frazier suction tube is equivalent to 6 French (6 Fr). French gauge is a standard measurement used for medical tubes and catheters, where 1 Fr equals approximately 0.33mm in diameter. A 6 Fr tube is the most commonly specified size for aural microsuction and fine ENT suction work.